FA2- TWO ZONE FIRE ALARM CONTROL MODULE
This compact, flush mount module provides two independently monitored
Fire Alarm zones with individual isolate switches common test and dim
switch. Designed for use in catamarans with twin engine rooms or monohull
vessels requiring engine room plus accommodation fire detection and
alarms.
|
The compact sealed FA2 two zone Fire Alarm
Control Module has a dash footprint of 48 x 96 mm, is flush mount,125mm
deep. Dash cut out 4x92mm.
The Full System Status Display is back illuminated by LED lightbars
for instant status recognition.
Label options include - Engine room & Accommodation Engine
rm & Ext release, Port & Stbd Eng rm, 1 & 2, and Engine
Rm & Generator Rm.
The four sealed touch switches provide reliable control even
in dirty, dusty or wet environments.
The red common Test switch starts a testing sequence which simulates
fault 1&2, isolated, normal, alarm 1, alarm 2, alarm 1&2,
and dim conditions at the detector inputs to fully test all audible
and visual a arms, ult monitoring circuits and remote alarm outputs.
Press test switch again to stop testing. In operation, test the
system on a regular basis.
The green Dim switch dims the Green Normal status display for
night time use. Alarm and Fault status displays are unaffected
by the Dim switch.
|
On detection of a Fire condition, (operation
of a fire detector on either detector zone) that zone's Red
FIRE indication flashes, accompanied by the local audible
Fire Alarm warning plus individual zone remote alarm output and
common remote alarm output. These alarms latch on until manually
reset.
If a Fault condition is detected which could
inhibit the fire alarm from operating the amber Fault
indication will illuminate for that zone accompanied
by a steady tone audible warning. These fault warnings latch on
until manually reset.
A typical Fault condition monitored for, would
include a break or high resistance joint in either detector circuit,
a detector out of circuit, or low battery voltage.
To reset the alarm or fault latches, press the
appropriate Isol/Reset switch twice, Once to Isolate the audible
alarms & Again to reset the panel to the Green Normal
condition. The system should always be left with the green Normal
Status display illuminated.
FA2 - EXTERNAL CONNECTIONS.
On the rear of the FA2 Two Zone Fire Alarm Control
Panel, there is a 13 way plug-in terminal for connection of all
external circuits
- Two 12 or 24 VDC Power Supplies, terminals 1&2,
& 3 & 4.
- The Port Fire Detector Circuit, terminals 5 & 6.
- The Stbd Fire Detector Circuit, terminals 7 & 8.
- Common Remote Alarm Output Circuit, terminals 9 &
10.
- Remote Zone Alarm output, Common Neg -ve terminal 11.
- Port Zone Remote Alarm Output, Pos +ve terminal 12.
- Stbd Zone Remote Alarm Output, Pos +ve terminal 13.
|
| Module depth = 125mm |
Dash Cut Out
= 44 x 92 mm |
|